Active Ventilation Products Keepa Vent will alleviate moisture in the winter and heat in the summer to extend the life of the roof and building structure. The Keepa Vent is best used for flat roof attic spaces as an exhaust roof vent or fresh air supply intake roof vent. Made of corrosion resistant aluminum, the Keepa Vent has a round concentric vent cap and standard 11 in. collar height, square flange and an inner louver wildlife guard. The vent cap is a manufactured one piece spun round aluminum cap that prevents rain and snow from entering the vent. The vent cap is removable to allow access for an easy rubber boot installation for membrane roofs. The 11 in. standard collar is excellent for locations that accumulate high levels of snow falls and the round design is aerodynamic to with stand wind speeds up to 200 mph. The Keepa Vent has proven to be an excellent and economical choice for a flat roof application.
Active Ventilation Products Keepa Vent will alleviate moisture in the winter and heat in the summer to extend the life of the roof and building structure. The Keepa Vent is best used for flat roof attic spaces as an exhaust roof vent or fresh air supply intake roof vent. Made of corrosion resistant aluminum, the Keepa Vent has a round concentric vent cap and standard 11 in. collar height, square flange and an inner louver wildlife guard. The vent cap is a manufactured one piece spun round aluminum cap that prevents rain and snow from entering the vent. The vent cap is removable to allow access
Gallery
Attributes
| Brand name, Manufacturer name, Brand | Active Ventilation |
|---|---|
| Manufacturer | Active Ventilation Active Ventilation Products, Inc. |
| AdultProduct, Autographed, Batteries_included, Batteries_required, Memorabilia, TradeInEligible | False |
| Asin | B00NO253V2 |
| Bullet_point | 5-year warranty Built-in inner vertical louver cylinder has a 1/8th in. opening between the louver blades and all aluminum (“noncombustible”) material meets the requirements of California building code 706A.2 vents to resist the intrusion of burning embers and flame through ventilation openings Florida Building Code Listed FL4763.3 Texas Department of Insurance ASTM E330 UL Certified R38772 |
| ClassificationId | 13399911 |
| DisplayName | Ducting |
| Generic_keyword | Roof Vents |
| Height | 1028 1029 1037 1111 15.98 1668 2560 359 465 485 500 54 70 73 75 |
| Identifier | 0843951008868 843951008868 |
| IdentifierType | EAN UPC |
| ItemClassification | BASE_PRODUCT |
| ItemName, Item_name | 12 in. Diameter Keepa Vent |
| Item_package_quantity, PackageQuantity | 1 |
| Item_package_weight, Weight | 4.5 |
| Item_type_keyword | ducting-components |
| Keyword | LOUVER |
| Length | 17.99 |
| Link | https://m.media-amazon.com/images/I/41BZHBJjFcL._SL75_.jpg https://m.media-amazon.com/images/I/41BZHBJjFcL.jpg https://m.media-amazon.com/images/I/41Mk0TwURaL._SL75_.jpg https://m.media-amazon.com/images/I/41Mk0TwURaL.jpg https://m.media-amazon.com/images/I/41PL327HJuL._SL75_.jpg https://m.media-amazon.com/images/I/41PL327HJuL.jpg https://m.media-amazon.com/images/I/41bz7Gq8ZzL._SL75_.jpg https://m.media-amazon.com/images/I/41bz7Gq8ZzL.jpg https://m.media-amazon.com/images/I/41jKuQOp+2L._SL75_.jpg https://m.media-amazon.com/images/I/41jKuQOp+2L.jpg https://m.media-amazon.com/images/I/5105HqhpWAL._SL75_.jpg https://m.media-amazon.com/images/I/5105HqhpWAL.jpg https://m.media-amazon.com/images/I/51Y0n59kFmL._SL75_.jpg https://m.media-amazon.com/images/I/51Y0n59kFmL.jpg https://m.media-amazon.com/images/I/61ZACcGP5-L.jpg https://m.media-amazon.com/images/I/61sUS79sQQL.jpg https://m.media-amazon.com/images/I/71G5v3uis9L.jpg https://m.media-amazon.com/images/I/71Mog4B5zuL.jpg https://m.media-amazon.com/images/I/71WcKc3HPIL.jpg https://m.media-amazon.com/images/I/91oelHEi1ZL.jpg https://www.amazon.com/gp/bestsellers/hi https://www.amazon.com/gp/bestsellers/hi/13399911 |
| Material | Aluminum |
| ModelNumber, Model_number, Mpns, PartNumber, Part_number | KV-12 |
| ProductType | HOME_LIGHTING_ACCESSORY |
| Product_description | Our Keepa Vents remove heat and moisture from the attic with no moving parts! Our UL certified Keepa Vent is tested to withstand wind pressure speeds up to 200 mph! Its standard 11 inch collar height is great for flat roof applications, especially for locations that accumulate high levels of snow or rain fall. Can be used as an air intake or exhaust roof vent. These vents have an all aluminum construction, which means it is durable, lightweight, and it WILL NOT RUST! Our Keepa Roof Vents have inner vertical louvers with an 1/8th inch diameter opening, thus maximizing air flow without letting in insects or animals. These are better than insect screens that clog up easily. And unlike your typical whirly-bird turbine vents, our keepa vents are not open to the sky, which prevents rain and snow from entering. The louver blades and noncombustible material meet the requirements of California building code 706A.2 Vents to resist the intrusion of burning embers and flame through ventilation openings. |
| Product_site_launch_date | 2014-09-17T17:41:23.739Z |
| Rank | 1674061 3943 |
| StrippedMpns | KV12 |
| Title | HVAC Ducting Tools & Home Improvement |
| Type | Count ean upc |
| Unit | inches pounds |
| Unit_count | 1.0 |
| Variant | MAIN PT01 PT02 PT03 PT04 PT05 PT06 |
| WebsiteDisplayGroup | home_improvement_display_on_website |
| WebsiteDisplayGroupName | Home Improvement |
| Width | 1069 1194 15.98 2281 2326 386 446 475 480 500 58 67 71 72 75 977 986 |
Distributor offers
| Seller | SKU | MOQ | In stock | Multiple | Prices |
|---|---|---|---|---|---|
![]() Home Depot | 204203059 | 1 | 1 @ $46.35 |
Related on Amazon
As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
- UL Certified R38772
- Florida Building Code Listed FL4763.3
- Texas Department of Insurance ASTM E330
- Built-in inner vertical louver cylinder has a 1/8th in. opening between the louver blades and all aluminum (“noncombustible”) material meets the requirements of California building code 706A.2 vents to resist the intrusion of burning embers and flame through ventilation openings
- 5-year warranty
