As an Amazon Associate, we earn from qualifying purchases.

U001-0063 Veris Industries Flow, SDI, SS, 1.5-10, Freq, No LCD - Special Order

Flow, SDI, SS, 1.5-10, Freq, No LCD - Special Order

Gallery

Attributes

Brand name, Manufacturer nameVeris Industries
ManufacturerVeris Industries Veris
Extra Product NameU001-0063 Veris Industries Flow, SDI, SS, 1.5-10, Freq, No LCD - Special Order
Weight2.000000 0.5 5.17
WeightUnitlbs
Weight_AttribWeight
jsonUrlData233775
keywordsindustrial refrigeration parts, ammonia, replacement parts, compressor parts
moq, multiple, tierMinQty1, Case, NumberOfItems, Number_of_items1
MPN, SKU, Part Number, Keyword, Model, PartNumber, Part_numberU001-0063
qtyInStockShips From Manufacturer
snippetFlow, SDI, SS, 1.5-10, Freq, No LCD - Special Order
tierPrice11253.37
Product GroupBISS
ConditionNew
ASIN, AsinB00CJL6ROQ
AdultProduct, Autographed, Memorabilia, TradeInEligibleFalse
Brand, Label, Man, Publisher, StudioVeris
Bullet_pointInsert Flow Meter Small Diameter Impeller (SDI)
CatIndustrial & Scientific
CatId16310091
CatTree16310091 16310161 256409011 4989323011
ClassificationId3206433011
DisplayNameFlowmeters
FeatureInsert Flow Meter
Height375 56
ItemClassificationBASE_PRODUCT
ItemName, Item_nameVeris,Flow,SDI,SS,1.5-10,Freq,No LCD, U001-0063
Item_type_keywordscience-lab-flowmeters
Item_weight0.5
Linkhttps://m.media-amazon.com/images/I/31MgwooOIXL._SL75_.jpg https://m.media-amazon.com/images/I/31MgwooOIXL.jpg
ProductGroupApparel BISS
ProductType, ProductTypeNameELECTRONIC_COMPONENT
Product_descriptionThe Veris direct insert style liquid flow sensor with stainless steel/PPS plastic or PEEK plastic tip combines flow sensing with a built-in transmitter for an all-in-one flow measuring system. This device fits all 1-1/2in to over 36in (38 to 915 mm) pipes, and it is intended for direct installation into the pipe through a 1in NPT hole. This sensor is available with or without hot tap capability. In the hot tap installation, the sensor is mounted in the pipe under pressure by attaching a service saddle or weld-on fitting to the pipe. Then the sensor assembly is attached to an isolation valve and extended into the pipeline to measure flow. Hot tap installations are often required in retrofit projects, but even in new construction, a hot tap sensor can be desirable for service considerations. Software and programming cable are required to operate these meters. If the meter will be used for hot tap installation, the A1027 tool is also needed (see Ordering Information). APPLICATIONS: Flow measuring projects, True hot tap installations, BTU applications (requires temperature sensors and transmitter/monitor)
Product_site_launch_date2013-04-26T23:54:19.059Z
TitleVeris Insert Flow Meter, Small Diameter Impeller (SDI). Part No. U001-0063 Veris,Flow,SDI,SS,1.5-10,Freq,No LCD, U001-0063
URLhttp://ecx.images-amazon.com/images/I/31MgwooOIXL._SL75_.jpg https://m.media-amazon.com/images/I/31MgwooOIXL._SL75_.jpg
Unitpounds
Unitspixels pounds
VariantMAIN
WebsiteDisplayGroupapparel_display_on_website
WebsiteDisplayGroupNameApparel
Width500 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
industrialrefrigerationparts.comU001-00631Ships From Manufacturer11 @ $1253.37
GalcoU001-0063-VEIN111 @ $1639.87
blackhawksupply.comU001-00631-211 @ $1112.45
alliedcontrols.comU001-00631Factory Stock11 @ $1036.80
associatedcontrolsinc.comU001-00631-211 @ $955.51

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Veris,Flow,SDI,SS,1.5-10,Freq,No LCD, U001-0063
Brand: Veris
The Veris direct insert style liquid flow sensor with stainless steel/PPS plastic or PEEK plastic tip combines flow sensing with a built-in transmitter for an all-in-one flow measuring system. This device fits all 1-1/2in to over 36in (38 to 915 mm) pipes, and it is intended for direct installation into the pipe through a 1in NPT hole. This sensor is available with or without hot tap capability. In the hot tap installation, the sensor is mounted in the pipe under pressure by attaching a service saddle or weld-on fitting to the pipe. Then the sensor assembly is attached to an isolation valve and extended into the pipeline to measure flow. Hot tap installations are often required in retrofit projects, but even in new construction, a hot tap sensor can be desirable for service considerations. Software and programming cable are required to operate these meters. If the meter will be used for hot tap installation, the A1027 tool is also needed (see Ordering Information). APPLICATIONS: Flow measuring projects, True hot tap installations, BTU applications (requires temperature sensors and transmitter/monitor)
Details
  • Insert Flow Meter
  • Small Diameter Impeller (SDI)
Listing
Product groupApparel
Product typeELECTRONIC_COMPONENT
ModelU001-0063
Part numberU001-0063
Items per pack1
LabelVeris
ManufacturerVeris
Catalog
FeatureInsert Flow Meter
CategoryIndustrial & Scientific
MPNU001-0063
Product groupBISS
Product typeELECTRONIC_COMPONENT
ManufacturerVeris
View on Amazon (paid link)