As an Amazon Associate, we earn from qualifying purchases.

ICM Ignition Control Board for Reznor | McCombs Supply Co | ICM2904

The ICM2904 is an intermittent pilot ignition control module from ICM Controls. It is suitable for use with intermittent pilot boilers, furnaces, and other heating appliances. The module is microprocessor-based and features remote flame sensing, brown out monitoring, and a 100% lockout safety feature. It operates within a temperature range of -40°F to 167°F and is compatible with LP or natural gas. The control voltage is 24V (18-30 VAC) at 50-60Hz.

Shop ICM Intermittent Pilot Gas Ignition Control Module for Reznor (257009). Number ICM2904. McCombs Supply Co. Fast Shipping!

Gallery

Attributes

Brand name, Manufacturer name, Manufacturer, Brand, Label, Publisher, StudioICM Controls
Extra Product NameICM Ignition Control Board for Reznor | McCombs Supply Co | ICM2904
moq, multiple, qtyInStock, tierMinQty11
MPN, SKU, Mpns, PartNumber, Part_number, StrippedMpnsICM2904
snippetShop ICM Intermittent Pilot Gas Ignition Control Module for Reznor (257009). Number ICM2904. McCombs Supply Co. Fast Shipping!
tierPrice193.51
ASINB084GTN2NW
AdultProduct, Autographed, Batteries_included, Batteries_required, Memorabilia, TradeInEligibleFalse
AsinB084GTN2NW B08RZ7NFT5
Bullet_pointAnticipator Setting: 2A plus valve load @ 24 VAC Bullet1 Control Voltage: Line 24V (18-30 VAC) 50-60Hz Ignition Type: Intermittent Pilot Pre-Purge Time: 0 Seconds Product Type: Intermittent Pilot Gas Ignition
ClassificationId10304191 13400031
DisplayNameCategories HVAC Controls
Height469 5.0 500 70 75
Identifier0800442032276 7423731249273 800442032276
IdentifierTypeEAN UPC
ItemClassificationBASE_PRODUCT
ItemName, Item_nameICM Controls ICM2904 OEM Gas Ignition Control Board Intermittent Pilot Ignition Control (Replaces Reznor 257009)
Item_package_weight1.0 2.0
Item_type_keywordhvac-controls
KeywordG5102456 ICM2904
Length9.0
Linkhttps://m.media-amazon.com/images/I/41I9-m7QpeL._SL75_.jpg https://m.media-amazon.com/images/I/41I9-m7QpeL.jpg https://m.media-amazon.com/images/I/51+cIkySDFL._SL75_.jpg https://m.media-amazon.com/images/I/51+cIkySDFL.jpg https://www.amazon.com/gp/bestsellers/hi https://www.amazon.com/gp/bestsellers/hi/13400031
ProductGroup, WebsiteDisplayGroupNameHome Improvement
ProductTypeCONTROLLER TOOLS
ProductTypeNameCONTROLLER
Product_description*Intermittent pilot gas ignition control module*For use with intermittent pilot boilers, furnaces and other heating appliances* Microprocessor-based*Remote flame sensing*Compatible with LP or natural gas*Brown out monitoring Features Intermittent Pilot Gas Ignition Control Module For use with intermittent pilot boilers, furnaces and other heating appliances Microprocessor-based Monitors timing, trial for ignition, and flame sensing Remote flame sensing 100% lockout safety feature Compatible with LP or Natural Gas Brown out monitoring circuit Specifications: Control Voltage: Line 18-30VAC 50/60 Hz Pilot Valve: 1A @24VAC Main Gas Valve: 2A @24VAC Current Draw: 100mA maximum Pre-Purge Delay: 0 seconds Ambient Operating Temperature: -40ºF to 167ºF -40C to 75C Humidity: 5%-95% R.H. (non-condensing) at +55C Specifications: Product Type: Intermittent Pilot Gas Ignition Control Voltage: Line 24V (18-30 VAC) 50-60Hz Anticipator Setting: 2A plus valve load @ 24 VAC Pre-Purge Time: 0 Seconds Ignition Type: Intermittent Pilot Operating Temp Range: -40 to 167F Relative Humidity: 5% to 95% R.H. (non condensing) Replaces: 257009 OEM: Reznor ICM Controls number ICM2904Intermittent Pilot Gas Ignition Control ModuleReplacement for Reznor 257009 and UTEC 1003-638A Features: For use with intermittent pilot boilers, furnaces, and other heating appliances Microprocessor-based Remote flame sensing Compatible with LP or natural gas Brown out monitoring circuit Instructions Included Specifications: Control Voltage: Line 18-30 VAC, 50/60 Hz Pilot Valve: 2A @ 24 VAC Main Gas Valve: 2A @ 24 VAC Current Draw: 100mA Maximum Pre-Purge Delay: 0 seconds Operating Temperature: -40F to 167F, -40C to 75C Humidity: 5%-95% R.H. (non-condensing) at +55C
Product_site_launch_date2020-01-24T20:37:14.860Z 2021-01-04T12:07:18.808Z
Rank1336 528637
Supplier_declared_dg_hz_regulationnot_applicable
TitleHVAC Controls ICM Controls ICM2904 OEM Gas Ignition Control Board Tools & Home Improvement
Typeean upc
URLhttps://m.media-amazon.com/images/I/51+cIkySDFL._SL75_.jpg
Unitinches pounds
Unitspixels pounds
VariantMAIN
WebsiteDisplayGrouphome_improvement_display_on_website
Weight1.0 2.0 2.00
Width500 7.0 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
mccombssupply.comICM29041111 @ $93.51
climatedoctors.comICM2904 REZ1311 @ $78.55
edmondsonsupply.comICM290411411 @ $90.99
skipthewarehouse.comICM29041-211 @ $81.04

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

ICM Controls ICM2904 OEM Gas Ignition Control Board
Brand: ICM Controls
ICM Controls number ICM2904Intermittent Pilot Gas Ignition Control ModuleReplacement for Reznor 257009 and UTEC 1003-638A Features: For use with intermittent pilot boilers, furnaces, and other heating appliances Microprocessor-based Remote flame sensing Compatible with LP or natural gas Brown out monitoring circuit Instructions Included Specifications: Control Voltage: Line 18-30 VAC, 50/60 Hz Pilot Valve: 2A @ 24 VAC Main Gas Valve: 2A @ 24 VAC Current Draw: 100mA Maximum Pre-Purge Delay: 0 seconds Operating Temperature: -40F to 167F, -40C to 75C Humidity: 5%-95% R.H. (non-condensing) at +55C
Details
  • Bullet1
Listing
Product groupHome Improvement
Product typeCONTROLLER
Part numberICM2904
LabelICM Controls
ManufacturerICM Controls
View on Amazon (paid link)
Intermittent Pilot Ignition Control (Replaces Reznor 257009)
Brand: ICM Controls
*Intermittent pilot gas ignition control module*For use with intermittent pilot boilers, furnaces and other heating appliances* Microprocessor-based*Remote flame sensing*Compatible with LP or natural gas*Brown out monitoring Features Intermittent Pilot Gas Ignition Control Module For use with intermittent pilot boilers, furnaces and other heating appliances Microprocessor-based Monitors timing, trial for ignition, and flame sensing Remote flame sensing 100% lockout safety feature Compatible with LP or Natural Gas Brown out monitoring circuit Specifications: Control Voltage: Line 18-30VAC 50/60 Hz Pilot Valve: 1A @24VAC Main Gas Valve: 2A @24VAC Current Draw: 100mA maximum Pre-Purge Delay: 0 seconds Ambient Operating Temperature: -40ºF to 167ºF -40C to 75C Humidity: 5%-95% R.H. (non-condensing) at +55C Specifications: Product Type: Intermittent Pilot Gas Ignition Control Voltage: Line 24V (18-30 VAC) 50-60Hz Anticipator Setting: 2A plus valve load @ 24 VAC Pre-Purge Time: 0 Seconds Ignition Type: Intermittent Pilot Operating Temp Range: -40 to 167F Relative Humidity: 5% to 95% R.H. (non condensing) Replaces: 257009 OEM: Reznor
Details
  • Product Type: Intermittent Pilot Gas Ignition
  • Control Voltage: Line 24V (18-30 VAC) 50-60Hz
  • Anticipator Setting: 2A plus valve load @ 24 VAC
  • Pre-Purge Time: 0 Seconds
  • Ignition Type: Intermittent Pilot