Electromagnetic Lock, Surface Mount, Opening Action Electromagnetic or Manual, Steel, Amp Draw @ 12V 1.25A/12V DC, Amp Draw @ 24V 0.76A/24V DC, Input Voltage 12/24V DC, Projection from Wall (In.) 3 in, Features Delayed Egress with Bond Sensor and Door Status Monitor for Double Outswing Door, Total Projection (In.) 3 in, Holding Force (Lb.) 1,500, Armature Length (In.) 10 1/2 in, Armature Width (In.) 2 5/8 in, Armature Depth (In.) 1/2 in, Lock Body Length (In.) 25 1/16 in
Electromagnetic Lock, Surface Mount, Opening Action Electromagnetic or Manual, Steel, Amp Draw @ 12V 1.25A/12V DC, Amp Draw @ 24V 0.76A/24V DC, Input Voltage 12/24V DC, Projection from Wall (In.) 3 in, Features Delayed Egress with Bond Sensor and Door Status Monitor for Double Outswing Door, Total Projection (In.) 3 in, Holding Force (Lb.) 1,500, Armature Length (In.) 10 1/2 in, Armature Width (In.) 2 5/8 in, Armature Depth (In.) 1/2 in, Lock Body Length (In.) 25 1/16 in
Gallery
Attributes
| Brand name, Manufacturer name | Schlage Electronics |
|---|---|
| Manufacturer | Schlage Electronics INGERSOLL RAND SECURITY TECHNOLOGY |
| CategoryId, CategoryIdL4 | 6244 |
| CategoryIdL1 | 27 |
| CategoryIdL2 | 17836 |
| CategoryIdL3 | 100361 |
| CategoryL1 | Hardware & Building Materials |
| CategoryL2 | Door Hardware & Components |
| CategoryL3 | Electromagnetic Locking Systems |
| CategoryL4 | Electromagnetic & Electromechanical Locks |
| DimensionUnit | inch |
| GTIN, UPC | None |
| GraingerSku | 28XY69 |
| UnitOfMeasure | EA |
| Voltage, Input Voltage | 12/24V DC |
| Weight | 30 29.7 |
| WeightUnit | lbs |
| cali_prop65_orglabel, cali_prop65_whtlabel, AdultProduct, Autographed, Memorabilia, TradeInEligible | False |
| countryOfOrigin | MX |
| height, length, moq, multiple, tierMinQty1, width, Item_package_quantity, Number_of_items, PackageQuantity | 1 |
| jsonUrlData | 924526ffbdad25e5923b |
| MPN, ModelNumber, Model_number, Mpns, PartNumber, Part_number | M490DEP-2 |
| qtyInStock | 0 |
| qtyInStockOverride | -2 |
| SKU | G8695985 |
| tierPrice1 | 4438.99 |
| url | https://www.zoro.com/schlage-electronics-electromagnetic-lock-1500lb-m490deseries-m490dep-2/i/G8695985/ |
| Lock Body Width (In ) | 3 1/16 in |
| Strike Plate Width (In ), Armature Width (In ) | 2 5/8 in |
| Strike Plate Length (In ), Armature Length (In ) | 10 1/2 in |
| Lock Body Depth (In ), Total Projection (In ) | 3 in |
| Armature Depth (In ), Strike Plate Depth (In ) | 1/2 in |
| Lock Body Length (In ) | 25 1/16 in |
| Item | Electromagnetic Lock |
| Type | Surface Mount Count |
| Opening Action | Electromagnetic or Manual |
| Finish | Clear Anodized |
| Options Included | Dual Voltage |
| For Use With | Delayed Egress System for Pairs of Doors |
| Holding Force (Lb ) | 1,500 |
| Material | Steel |
| Mfr Series | M490DE |
| Amp Draw @ 12V | 1.25A/12V DC |
| Features | Delayed Egress with Bond Sensor and Door Status Monitor for Double Outswing Door |
| Amp Draw @ 24V | 0.76A/24V DC |
| Asin | B00GFJ0Q22 |
| Brand | SCHLAGE |
| Bullet_point | Automatic voltage selection feature distinguishes between a 12-or 24-VDC electrical connection and adjusts automatically, and the automatic surge suppressor protects the equipment from damage if voltage spikes Delayed-egress feature prevents exit for 15 seconds while an audible alarm sounds and is designed to meet the NFPA 101 Life Safety Code Door-status and magnetic-bond sensors communicate with an access control system to identify an open or closed door and monitor the strength of the magnetic connection, and the lock can be programmed with a 0.5- to 30-second relock delay Electromagnetic lock with a 1,500-lb. holding force per electromagnet connects to a door access system such as a push bar, request-to-exit device, or credential reader to create a maximum-security locking system for double inswing or outswing doors Fail-safe design loses magnetism and unlocks when power is removed |
| ClassificationId | 573758011 |
| Control_method | remote |
| Currency | USD |
| DisplayName | Handlesets |
| Finish_type | Satin Chrome |
| Height | 1000 11.938 4.699999995206 500 75 |
| ItemClassification | BASE_PRODUCT |
| ItemName, Item_name | Schlage Electronics M490DEP-2 Delayed Egress Maximum-Security Electromagnetic Lock, For Access Control System, Double Door, 1,500-lb. Holding Force Per Electromagnet |
| Item_package_weight | 29.7 |
| Item_type_keyword | door-handles |
| Length | 14.599999985108 37.083999999999996 |
| Link | https://m.media-amazon.com/images/I/41SEypP7fqL._SL75_.jpg https://m.media-amazon.com/images/I/41SEypP7fqL.jpg https://m.media-amazon.com/images/I/51SO8mepAbL.jpg |
| List_price | 3972.0 |
| Lock_type | Keypad |
| ProductType | LOCK |
| Product_site_launch_date | 2012-09-28T02:44:33.202Z |
| StrippedMpns | M490DEP2 |
| Unit | centimeters inches pounds |
| Unit_count | 1.0 |
| Variant | MAIN |
| WebsiteDisplayGroup | biss_basic_display_on_website |
| WebsiteDisplayGroupName | BISS Basic |
| Width | 1000 12.299999987454 31.242 500 75 |
Distributor offers
| Seller | SKU | MOQ | In stock | Multiple | Prices |
|---|---|---|---|---|---|
| G8695985 | 1 | 1 | 1 @ $4438.99 | ||
| 28XY69 | 1 | 1 | 1 @ $4439.82 | ||
| M490DEP-2 | 1 | 1 | 1 @ $4138.96 | ||
| sustainablesupply.com | C1713587 | 1 | -2 | 1 | 1 @ $3911.60 |
![]() keylessaccesslocks.com | M490DEP-2 | 1 | 1 | ||
| SCH_M490DEP2 | 1 | 10 | 1 | 1 @ $3547.68 |
Related on Amazon
As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Schlage Electronics M490DEP-2 Delayed Egress Maximum-Security Electromagnetic Lock, For Access Control System, Double Door, 1,500-lb. Holding Force Per Electromagnet
Brand: SCHLAGE
Details
- Electromagnetic lock with a 1,500-lb. holding force per electromagnet connects to a door access system such as a push bar, request-to-exit device, or credential reader to create a maximum-security locking system for double inswing or outswing doors
- Delayed-egress feature prevents exit for 15 seconds while an audible alarm sounds and is designed to meet the NFPA 101 Life Safety Code
- Door-status and magnetic-bond sensors communicate with an access control system to identify an open or closed door and monitor the strength of the magnetic connection, and the lock can be programmed with a 0.5- to 30-second relock delay
- Automatic voltage selection feature distinguishes between a 12-or 24-VDC electrical connection and adjusts automatically, and the automatic surge suppressor protects the equipment from damage if voltage spikes
- Fail-safe design loses magnetism and unlocks when power is removed