Markel Y3484A1 Electric Ceiling Heater
Attributes
| Brand name, Manufacturer name | MARKEL |
|---|---|
| Manufacturer | MARKEL Markel TPI |
| KnownMan, Extra Product Name | Markel Y3484A1 Electric Ceiling Heater |
| moq, multiple, tierMinQty1, Item_package_quantity, Number_of_items, PackageQuantity | 1 |
| MPN, Keyword, ModelNumber, Model_number, PartNumber, Part_number | Y3484A1 |
| qtyInStock | 0 |
| tierPrice1 | 1348.03 |
| ASIN | B00BJQGZ4Y |
| AdultProduct, Autographed, Batteries_required, Memorabilia, TradeInEligible | False |
| Asin | B001C2BYVO B00BJQGZ4Y |
| Binding | Misc. |
| Brand, Label, Publisher, Studio | Markel |
| Bullet_point | Air Flow: 425 CFM Amperage Rating: 4.8 AMP Btu Rating: 13600 Manual Reset Thermal Limit Manufactured in U.S.A. |
| ClassificationId | 516188 |
| Color | White |
| Currency | USD |
| DisplayName | Heaters & Accessories |
| Heat_output | 13600.0 |
| Heating_element_type | Radiant |
| Heating_method | Forced Air |
| Height | 1000 23.06 260 500 6 6.0 75 |
| Identifier | 0686334318587 686334318587 |
| IdentifierType | EAN UPC |
| ItemClassification | BASE_PRODUCT |
| ItemName, Item_name | Markel Y3484A1 Recess Mounted Ceiling Heater, 4KW, 480V 3PH 4.8A TPI Y3484A1 3480 Series Commercial Fan Forced Recessed Mounted Ceiling Heater, Three Phase, 4KW, 480V 3PH 4.8A, White |
| Item_display_weight, Item_weight | 50.0 |
| Item_package_weight | 50.01 |
| Item_type_keyword | heaters |
| Length | 22 22.0 9.13 |
| Link | https://m.media-amazon.com/images/I/31KyC1ccVJL._SL75_.jpg https://m.media-amazon.com/images/I/31KyC1ccVJL.jpg https://m.media-amazon.com/images/I/31gOlKiZ91L._SL75_.jpg https://m.media-amazon.com/images/I/31gOlKiZ91L.jpg https://m.media-amazon.com/images/I/417w8WyAmvL.jpg |
| List_price | 1346.56 |
| Mounting_type | Ceiling Mount |
| Power_source_type | Corded Electric |
| ProductGroup | Home Improvement |
| ProductType | SPACE_HEATER |
| ProductTypeName | TOOLS |
| Product_description | - White powder coated 20 Gauge grill.- 208V, 240V, & 277V units have manual reset thermal limit.- 480V units have manual reset thermal limit, 24V control transformer, and 24V relay (A1 suffix).- Enclosed steel fin sheath element.- Rough in dimensions: 23-1/16" sq. x 9-1/8" deep.Product SpecificationsContractor shall supply and install heavy duty ceiling mounted forced air electric heater(s) of the wattage, voltage and phase as indicated on the plans. The heater shall be so designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by means of an electric motor and axial flow fan blade. Heaters shall be recessed type and mounted flush with the finished ceiling. The return grille assembly shall be constructed of a one piece heavy gauge steel with 1/4" slots for return air and concentric rings for uniform air discharge. Grille assembly shall be attached to chassis by tamper-resistant (allen head) machine screws. All parts of enclosure shall be heavy Gauge steel, zinc coated both sides and finished in neutral off white powder coat paint. Enclosure shall be constructed of 1/6" x 3/8" rounded edge horizontal steel louvers which shall be spaced for maximum opening of 5/16". Louvers shall be welded at every intersection to evenly spaced 1/8" diameter vertical members. Motor shall be permanent lubricated, unit bearing, totally enclosed, impedance protection. Motors shall operate at no more than 1300 RPM and shall be same voltage as the heater. Heaters shall have a rating of 425 CFM at 710 F.P.M. Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant steel fins. Each sheathed element shall consist of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded by magnesi |
| Product_site_launch_date | 2010-02-26T09:51:47.000-00:00 2013-02-22T21:53:29.289Z |
| Room_type | Bedroom Home Office Living Room |
| Special_feature | Manual Thermostat |
| Title | Markel Y3484A1 Recess Mounted Ceiling Heater, 4KW, 480V 3PH 4.8A |
| Type | Count ean upc |
| URL | https://m.media-amazon.com/images/I/31KyC1ccVJL._SL75_.jpg |
| Unit | btus inches pounds volts watts |
| Unit_count | 1.0 |
| Units | pixels |
| Variant | MAIN |
| Voltage | 480.0 |
| Wattage | 4.0 |
| WebsiteDisplayGroup | biss_basic_display_on_website kitchen_display_on_website |
| WebsiteDisplayGroupName | BISS Basic Kitchen |
| Weight | 50 50.01 |
| Width | 1000 18 18.0 23.06 260 500 75 |
Distributor offers
| Seller | SKU | MOQ | In stock | Multiple | Prices |
|---|---|---|---|---|---|
| h-mac.com | MARKEL-Y3484A1 | 1 | 1 | 1 @ $1348.03 |
Related on Amazon
As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
TPI Y3484A1 3480 Series Commercial Fan Forced Recessed Mounted Ceiling Heater, Three Phase, 4KW, 480V 3PH 4.8A, White
Brand: Markel
Details
- Manual Reset Thermal Limit
- Manufactured in U.S.A.
- Btu Rating: 13600
- Amperage Rating: 4.8 AMP
- Air Flow: 425 CFM
Markel Y3484A1 Recess Mounted Ceiling Heater, 4KW, 480V 3PH 4.8A
Brand: Markel
- White powder coated 20 Gauge grill.- 208V, 240V, & 277V units have manual reset thermal limit.- 480V units have manual reset thermal limit, 24V control transformer, and 24V relay (A1 suffix).- Enclosed steel fin sheath element.- Rough in dimensions: 23-1/16" sq. x 9-1/8" deep.Product SpecificationsContractor shall supply and install heavy duty ceiling mounted forced air electric heater(s) of the wattage, voltage and phase as indicated on the plans. The heater shall be so designed to provide an even distribution of heated air to the space to be heated by drawing return air in the periphery of the heater, across and through the element and be discharged from the center section of the heater by means of an electric motor and axial flow fan blade. Heaters shall be recessed type and mounted flush with the finished ceiling. The return grille assembly shall be constructed of a one piece heavy gauge steel with 1/4" slots for return air and concentric rings for uniform air discharge. Grille assembly shall be attached to chassis by tamper-resistant (allen head) machine screws. All parts of enclosure shall be heavy Gauge steel, zinc coated both sides and finished in neutral off white powder coat paint. Enclosure shall be constructed of 1/6" x 3/8" rounded edge horizontal steel louvers which shall be spaced for maximum opening of 5/16". Louvers shall be welded at every intersection to evenly spaced 1/8" diameter vertical members. Motor shall be permanent lubricated, unit bearing, totally enclosed, impedance protection. Motors shall operate at no more than 1300 RPM and shall be same voltage as the heater. Heaters shall have a rating of 425 CFM at 710 F.P.M. Element assemblies shall consist of two or three corrosion resistant steel sheathed type elements mechanically bonded to common corrosion resistant steel fins. Each sheathed element shall consist of helically coiled Nickel Chromium alloy resistant wire completely embedded in and surrounded by magnesi
Listing
| Binding | Misc. |
|---|---|
| Product group | Home Improvement |
| Product type | TOOLS |
| Part number | Y3484A1 |
| Label | Markel |
| Manufacturer | Markel |