Onset HOBO S-WSET-B Wind Speed & Direction Sensor Set | Transcat
Attributes
| Brand name, Manufacturer name | ONSET HOBO |
|---|---|
| Manufacturer | ONSET HOBO Onset Computer |
| KnownMan, Extra Product Name | Onset HOBO S-WSET-B Wind Speed & Direction Sensor Set | Transcat |
| moq, multiple, tierMinQty1, Color, Item_package_quantity, Number_of_items, PackageQuantity | 1 |
| MPN, SKU, Keyword, ModelNumber, Model_number, Mpns, PartNumber, Part_number | S-WSET-B |
| qtyInStock | 0 |
| tierPrice1 | 560 |
| AdultProduct, Autographed, Memorabilia, TradeInEligible | False |
| Asin | B07SPV3M3Q |
| Brand | Onset |
| Bullet_point | Three-cup Lexan anemometer with Teflon bearings and hardened beryllium shaft |
| ClassificationId | 16310161 |
| Currency | USD |
| DisplayName | Categories |
| Height | 500 75 8.0 |
| ItemClassification | BASE_PRODUCT |
| ItemName, Item_name | Onset S-WSET-B Wind Sensor Set Measures Wind Speed (S-WSB-M003) & Direction (S-WDA-M003) |
| Item_type_keyword | anemometers |
| Item_weight, Weight | 2.35 |
| Length | 24.0 |
| Link | https://m.media-amazon.com/images/I/41sEv74H7CL._SL75_.jpg https://m.media-amazon.com/images/I/41sEv74H7CL.jpg |
| List_price | 830.39 |
| ProductType | PRECISION_MEASURING |
| Product_description | Three-cup Lexan anemometer with Teflon bearings and hardened beryllium shaft. Requires cross arm mount.Specifications:Parameters: average wind speed, highest 3-second wind gust, average wind direction (unit vector average). Measurement Range: Wind Speed/Gust, 0 to 76 m/s (0 to 170 mph); Wind Direction, 0 to 355°, 5° dead band. Maximum Wind Speed Survival: Wind Speed/Gust, 76 m/s (170 mph); Wind Direction, 67 m/s (150 mph). Accuracy: Wind Speed/Gust, ±1.1 m/s (±2.4 mph) or ±4% of reading, whichever is greater; Wind Direction, ±5°. Resolution: Wind Speed/Gust, 0.5 m/s (1.1 mph); Wind Direction, 1.4°. Starting Threshold: Wind Speed/Gust, 1.0 m/s (2.2 mph); Wind Direction, 1.0 m/s (2.2 mph). Length of Smart Sensor Network Cable: 0.5m (1.6´). Operating Temperature Range: Wind Speed/Gust, -40°F to 167°F (-40°C to 75°C); Wind Direction, -40°F to 158°F (-40°C to 70°C). Three-cup Lexan anemometer with Teflon bearings and hardened beryllium shaft. Requires cross arm mount.Specifications:Parameters: average wind speed, highest 3-second wind gust, average wind direction (unit vector average). Measurement Range: Wind Speed/Gust, 0 to 76 m/s (0 to 170 mph); Wind Direction, 0 to 355°, 5° dead band. Maximum Wind Speed Survival: Wind Speed/Gust, 76 m/s (170 mph); Wind Direction, 67 m/s (150 mph). Accuracy: Wind Speed/Gust, ±1.1 m/s (±2.4 mph) or ±4% of reading, whichever is greater; Wind Direction, ±5°. Resolution: Wind Speed/Gust, 0.5 m/s (1.1 mph); Wind Direction, 1.4°. Starting Threshold: Wind Speed/Gust, 1.0 m/s (2.2 mph); Wind Direction, 1.0 m/s (2.2 mph). Length of Smart Sensor Network Cable: 0.5m (1.6´). Operating Temperature Range: Wind Speed/Gust, -40°F to 167°F (-40°C to 75°C); Wind Direction, -40°F to 158°F (-40°C to 70°C). |
| Product_site_launch_date | 2019-06-04T19:19:07.680Z |
| StrippedMpns | SWSETB |
| Unit | inches pounds |
| Variant | MAIN |
| WebsiteDisplayGroup | biss_basic_display_on_website |
| WebsiteDisplayGroupName | BISS Basic |
| Width | 11.0 500 75 |
Distributor offers
| Seller | SKU | MOQ | In stock | Multiple | Prices |
|---|---|---|---|---|---|
| Transcat | S-WSET-B | 1 | 1 | 1 @ $560.00 | |
| MicroDAQ | S-WSET-B | 1 | 1 |
Related on Amazon
As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.
Onset S-WSET-B Wind Sensor Set Measures Wind Speed (S-WSB-M003) & Direction (S-WDA-M003)
Brand: Onset
Three-cup Lexan anemometer with Teflon bearings and hardened beryllium shaft. Requires cross arm mount.Specifications:Parameters: average wind speed, highest 3-second wind gust, average wind direction (unit vector average). Measurement Range: Wind Speed/Gust, 0 to 76 m/s (0 to 170 mph); Wind Direction, 0 to 355°, 5° dead band. Maximum Wind Speed Survival: Wind Speed/Gust, 76 m/s (170 mph); Wind Direction, 67 m/s (150 mph). Accuracy: Wind Speed/Gust, ±1.1 m/s (±2.4 mph) or ±4% of reading, whichever is greater; Wind Direction, ±5°. Resolution: Wind Speed/Gust, 0.5 m/s (1.1 mph); Wind Direction, 1.4°. Starting Threshold: Wind Speed/Gust, 1.0 m/s (2.2 mph); Wind Direction, 1.0 m/s (2.2 mph). Length of Smart Sensor Network Cable: 0.5m (1.6´). Operating Temperature Range: Wind Speed/Gust, -40°F to 167°F (-40°C to 75°C); Wind Direction, -40°F to 158°F (-40°C to 70°C). Three-cup Lexan anemometer with Teflon bearings and hardened beryllium shaft. Requires cross arm mount.Specifications:Parameters: average wind speed, highest 3-second wind gust, average wind direction (unit vector average). Measurement Range: Wind Speed/Gust, 0 to 76 m/s (0 to 170 mph); Wind Direction, 0 to 355°, 5° dead band. Maximum Wind Speed Survival: Wind Speed/Gust, 76 m/s (170 mph); Wind Direction, 67 m/s (150 mph). Accuracy: Wind Speed/Gust, ±1.1 m/s (±2.4 mph) or ±4% of reading, whichever is greater; Wind Direction, ±5°. Resolution: Wind Speed/Gust, 0.5 m/s (1.1 mph); Wind Direction, 1.4°. Starting Threshold: Wind Speed/Gust, 1.0 m/s (2.2 mph); Wind Direction, 1.0 m/s (2.2 mph). Length of Smart Sensor Network Cable: 0.5m (1.6´). Operating Temperature Range: Wind Speed/Gust, -40°F to 167°F (-40°C to 75°C); Wind Direction, -40°F to 158°F (-40°C to 70°C).
Details
- Three-cup Lexan anemometer with Teflon bearings and hardened beryllium shaft