As an Amazon Associate, we earn from qualifying purchases.

Azel Technologies . SZ-84DX

Attributes

Brand name, Manufacturer nameAzel Technologies
ManufacturerAzel Technologies Azel Technologies Inc.
atoms, moq, multiple, Item_package_quantity, Number_of_items, PackageQuantity1
extendedQty, qtyInStock0
MPN, ModelNumber, Model_number, Mpns, PartNumber, Part_numberSZ-84DX
AdultProduct, Autographed, Batteries_included, Batteries_required, Memorabilia, TradeInEligibleFalse
AsinB00GSBEBOG
BrandAzel Technologies Inc.
ClassificationId3206324011 322525011
ColorMulti
Control_methodapplication
CurrencyUSD
DisplayNameLight Bulbs
Height1631 2.8 492 74
Identifier0640350035514 640350035514
IdentifierTypeEAN UPC
ItemClassificationBASE_PRODUCT
ItemName, Item_nameAzel SZ-84DX Four Zone Valve Controls for Hydronic Radiant Floor Heating Systems
Item_type_keywordled-household-light-bulbs
KeywordINC
Length6.5
Light_typeLED
Linkhttps://m.media-amazon.com/images/I/41z5sIE4IvL._SL75_.jpg https://m.media-amazon.com/images/I/41z5sIE4IvL.jpg https://m.media-amazon.com/images/I/71XbyeDQ0nL.jpg https://www.amazon.com/gp/bestsellers/home-garden/3206324011 https://www.amazon.com/gp/bestsellers/industrial https://www.amazon.com/gp/bestsellers/industrial/322525011
List_price115.0
ProductTypeLIGHT_BULB
Product_descriptionThe i-Link series Zone Valve Controls simplify the field wiring and yet control up to four zone valves in a multi-zone hydronic heating system. The contractor friendly Printed Circuit Board eliminates the problem caused by incorrect wiring and saves hours of installation time. There would be no more “messy” look of conventional zone valve installations. Intelligent Linking System (i-Link) allows unlimited zone expansion with additional i-Link controllers. Field selectable priority with Priority Protection Timer ensures other zones get heat every one hour and prevents freeze-ups in the event of a priority zone failure. The End Switch delay timer let the two wire type zone valves fully opened before turning on the circulator. The panel provides EZ screwless terminal blocks for connections to the thermostats and zone valves. In addition, LED indicators on the front panel provide functional status and easy troubleshooting. Product Features and Benefits: * Front panel indicator lights * Field selectable Priority * Priority timer for protection of a priority zone malfunction and prevention of freeze-ups in the heating zones * Unlimited zone expansion * Dual Isolated End Switches * Three-minute End Switch delay timer for two wire type zone valve applications. Circulator will start only after the zone valve is fully opened. * DIP switch for easy setup of two wire type zone valve applications. No need to hook up wire jumper on the third and fourth terminals on each zone * Works with two, three or four wire type zone valves and thermostats * Compact and modern design * Safety design with all electronic components hiding behind the enclosure * Fuse protection * Simplified wiring * Contractor friendly PCB layout * Easy-Connect Screwless Terminals * 24VAC transformer output with common terminal provides compatibility with electronic thermostats * Universal thermostat compatibility * 100% Factory Tested * Dual Isolated End Switches * Extended three year warranty
Product_site_launch_date2013-11-02T07:00:00.000Z
Rank48389 626466 63659
StrippedMpnsSZ84DX
TitleHeating, Cooling & Air Quality Industrial & Scientific Light Bulbs
TypeCount LED ean upc
Unitinches
Unit_count1.0
VariantMAIN
WebsiteDisplayGroupbiss_display_on_website lighting_display_on_website
WebsiteDisplayGroupNameLighting
Width1658 500 6.5 75

Distributor offers

SellerSKUMOQIn stockMultiplePrices
SupplyHouseSZ-84DX11

Related on Amazon

As an Amazon Associate, we earn from qualifying purchases. (paid link) CERTAIN CONTENT THAT APPEARS ON THIS SITE COMES FROM AMAZON. THIS CONTENT IS PROVIDED 'AS IS' AND IS SUBJECT TO CHANGE OR REMOVAL AT ANY TIME.

Azel SZ-84DX Four Zone Valve Controls for Hydronic Radiant Floor Heating Systems
Brand: Azel Technologies Inc.
The i-Link series Zone Valve Controls simplify the field wiring and yet control up to four zone valves in a multi-zone hydronic heating system. The contractor friendly Printed Circuit Board eliminates the problem caused by incorrect wiring and saves hours of installation time. There would be no more “messy” look of conventional zone valve installations. Intelligent Linking System (i-Link) allows unlimited zone expansion with additional i-Link controllers. Field selectable priority with Priority Protection Timer ensures other zones get heat every one hour and prevents freeze-ups in the event of a priority zone failure. The End Switch delay timer let the two wire type zone valves fully opened before turning on the circulator. The panel provides EZ screwless terminal blocks for connections to the thermostats and zone valves. In addition, LED indicators on the front panel provide functional status and easy troubleshooting. Product Features and Benefits: * Front panel indicator lights * Field selectable Priority * Priority timer for protection of a priority zone malfunction and prevention of freeze-ups in the heating zones * Unlimited zone expansion * Dual Isolated End Switches * Three-minute End Switch delay timer for two wire type zone valve applications. Circulator will start only after the zone valve is fully opened. * DIP switch for easy setup of two wire type zone valve applications. No need to hook up wire jumper on the third and fourth terminals on each zone * Works with two, three or four wire type zone valves and thermostats * Compact and modern design * Safety design with all electronic components hiding behind the enclosure * Fuse protection * Simplified wiring * Contractor friendly PCB layout * Easy-Connect Screwless Terminals * 24VAC transformer output with common terminal provides compatibility with electronic thermostats * Universal thermostat compatibility * 100% Factory Tested * Dual Isolated End Switches * Extended three year warranty
View on Amazon (paid link)