Attributes . Coverage is effective (frequency response similar) beyond the traditional -6 dB coverage angles. This is especially useful in compensating for differences in listening distances. Figures show both the -6 dB and -12 dB coverage angles (at 3 kHz). Angles are in reference to cabinet aiming axis. Pattern UP Settings: "Point": -6dB at +7°, -12 dB at +12° "Tight": -6dB at +9°, -12 dB at +15° "Narrow": -6dB at +10°, -12 dB at +20° "Medium": -6dB at +13°, -12 dB at +24° Pattern DOWN Settings: "Point": -6dB at -7°, -12 dB at -12° "Narrow": -6dB at -10°, -12 dB at -20° "Broad": -6dB at -17°, -12 dB at -28° "Downfill": -6dB at -20°, -12 dB at -35° . Names