dataSource: amazonScraper

Products with this attribute (63960 total)

Tork 7120Z-45 SunSet with Skip-A-Day Astronomic Time Switch - 45 Degrees This is only to be used on a clock located in the 45 degree latitude zone (or call Tork at 888-500-4598 for the correct part for your location).APPLICATIONS:Parking Lots, Walkways, Outdoor Signage, Window Displays, Canopy Lighting, Landscape Lighting Automatic ON at dusk, OFF at dawn. Control of outdoor lighting. FEATURES: INPUT VOLTAGE: 120 VAC 60 Hz OUTPUT CONTACTS: SPDT TIMING ACCURACY: Line frequency TERMINAL RANGE: #8 - #14 AWG OPERATING TEMPERATURE: -40 degrees to 165 degrees F (-40 degrees to +74 degrees C) POWER CONSUMPTION: 3 watts maximum SunSet ASTRONOMIC: Adjusts daily to changes in sunset times. Turn ON at sunset and OFF at sunrise daily. OFF time can be set from 8:30PM to 2:30AM. Can be individually offset + / - 20 or 40 minutes from both sunset and OFF times. TRIPPERS: Comes with (1) set of trippers ( 1 ON and 1 OFF). Additional trippers can be purchased under Part # P49. SKIP-A-DAY: Omit operations on any day with a 7-spoke wheel marked with days of the week. 3 omitting screws included. MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. ENCLOSURE: Lockable hasp. Noryl Indoor/Outdoor NEMA 3R OTHER MOUNTINGS: Intermatic Adaptor Plate model #IAP allows adaptation to an Intermatic case. MANUFACTURER: Tork PART NUMBER: 7120Z-45 UPC: 786261230096 CONTACT RATINGS: GENERAL PURPOSE: 120VAC Single Phase. Contact Rating 40A RESISTIVE: 120VAC Single Phase. Contact Rating 40A TUNGSTEN: 120VAC. Contact Rating 40A BALLAST: 120VAC Single Phase. Contact Rating 20A PILOT DUTY: 120VAC. Contact Rating 1000VA MOTOR: 120VAC Single Phase. Contact Rating 2HP We have timers to fit your every need, with the best selection and prices.
Tork DG200A 365/7 Day 2 Channel SPDT Digital Time SwitchAPPLICATIONS:Indoor/Outdoor LightingHVAC EquipmentSchool Warning and OtherTraffic LightsWater Heaters in Offices, Churches and FactoriesFEATURES:TIMING ACCURACY: Line FrequencyINPUT VOLTAGE: 120-277 50/60HzDRY CONTACTS: SPDTTERMINAL RANGE: #14-#18AWGOPERATING TEMPERATURE: -31 degrees to +131 degrees F (-35 degrees to 55 degrees C)POWER CONSUMPTION: 6VA MaxSCHEDULING: 56 ON & OFF set points provide individual programs for each day of the week. Minimum setting is 1 minute.BLOCK HOLIDAY: 9 holiday blocks can be set for individual days or for duration of any number of days.DAYLIGHT SAVINGS: Automatic adjustment (can be omitted).LEAP YEAR: Automatic compensation.MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM or Military time.POWER OUTAGE BACKUP: Permanent schedule retention. Super-capacitor provides 7 days of real time backup.ENCLOSURE: Noryl Indoor/Outdoor NEMA 3R with lockable hasp.BRAND EQUIVALENT: Paragon EL7200PC/208-240MANUFACTURER: TorkPART NUMBER: DG200AUPC: 786261822093CONTACT RATINGS:GENERAL PURPOSE: 24-277VAC. Contact Rating NO: 20A NC: 10ABALLAST: 120VAC. Contact Rating NO: 20A NC: 10A 277VAC. Contact Rating NO: 20A NC: 10ATUNGSTEN: 120VAC. Contact Rating NO: 15APILOT DUTY: 120VAC. Contact Rating NO: 720VA NC: 290VA 240VAC. Contact Rating NO: 720VA NC: 360VAMOTOR LOAD: 120VAC. Contact Rating NO: 1HP NC: 1/4HP 240VAC. Contact Rating NO: 2HP NC: 1/2HPRESISTIVE: 28VDC. Contact Rating NO: 20A NC: 10AWe have timers to fit your every need, with the best selection and prices.
Trade Name: Amicon. Key Applications: Protein Purification, Western Blotting and Protein Extraction. Application Notes: Fixed angle rotor: 14,000 x g for concentration spin; 1,000 x g for reverse spin. Length, cm (in): 4.99 (0.196). Filter Material: Regenerated Cellulose. Centrifugal Application: Protein Concentration and Desalting. Centrifugal Filter Unit Type: Protein Sample Prep. Color Code: Clear. Media Brand Name: Ultracel. Minimum Final Concentrate Volume,?L: 15. Filter Type: Ultrafiltration. Length,mm: 49.9. NMWL, kDa: 100. Replaces: 42424. Diameter,mm: 10.8. Filter Code: YML. Volume, mL: 0.5. Filtration Area, cm squared: 1. Device Material: Housing: Styrene/butadiene and Cap and Tube: Polypropylene. Material Supplied: The Amicon Ultra-0.5 device is supplied with two microcentrifuge tubes. During operation, one tube is used to collect filtrate; the other tube is to recover the concentrated sample. Maximum initial sample volume,?L: 500. Typical final concentration volume,?L: 15 - 20. Recommended relative centrifugal force: 14,000 x g for concentration spin; 1,000 x g for reverse spin. Maximum relative centrifugal force: 15,000 x g. Active membrane area, cm squared: 1. Hold up volume,?L: <=1. Filter device: Copolymer styrene/butadiene. Membrane: Millipore Ultracell low-binding regenerated cellulose. Collection tube: Polypropylene. The ultrafiltration membranes in Amicon Ultra-0.5 mL devices contain trace amounts of the following:: Amicon Ultra 3K devices: glycerine; Amicon Ultra 10K device: triethylene glycol (TEG). If these materials interfere with analysis, pre-rinse the device with buffer or Milli-Q water. If interference continues, rinse with 0.1 N NaOH followed by a second spin of buffer or Milli-Q water. Filter device: Diameter: 9.4mm and 29.6mm Length. Tube: 10.8mm Diameter and 43.0mm Length. Filter device and tube: 49.9mm Length (concentration mode; device in tube); 37.3mm Length (reverse spin; device upside down in tube).