<p><strong>GA International also known as LabTAG, JTTA-137C1-4OR, Cryogenic Barcode Labels for Liquid Nitrogen Storage, 1" Core, Orange </strong> </p> <p>Cryogenic labels for the identification of small diameter vials & tubes, plates, cardboard freezer boxes, polypropylene cryo boxes, and plastic bags. Designed for long-term cryo-preservation under cryogenic laboratory conditions including liquid helium (-269°C / -452.2°F), liquid and vapor phase liquid nitrogen (-196°C / -320.8°F), -80°C (-112°F) freezers and dry ice transportation. Labels can be printed with all major brands of thermal-transfer printers. </p> <p><strong>Features: </strong> </p> <ul><li>Resistant to extreme cryogenic conditions – as low as -269°C </li> <li>Require zero cure time, can be immersed in liquid nitrogen immediately following application </li> <li>Adhere to wet and moist surfaces </li> <li>Labels are resistant to spraying and swabbing with alcohol and surface sanitizing wipes </li> <li>Permanent adhesion, especially on curved surfaces (vials, microtubes, etc.) </li> <li>Resistant to gamma irradiation (tested to up to 50kGy) </li> </ul> <table cellspacing="1" cellpadding="2" border="0" width="100%" class="dataTable"><tr><td>Unit of Measure </td> <td>Roll of 4000 labels </td> </tr> </table>
<p><strong>GA International also known as LabTAG, JTTA-179C1-1WH, Nitrotag Cryogenic Barcode Label for Liquid Nitrogen Storage, 2.75" x 1.25", 1" Core </strong> </p> <p>Cryogenic labels for the identification of small diameter vials & tubes, plates, cardboard freezer boxes, polypropylene cryo boxes, and plastic bags. Designed for long-term cryo-preservation under cryogenic laboratory conditions including liquid helium (-269°C / -452.2°F), liquid and vapor phase liquid nitrogen (-196°C / -320.8°F), -80°C (-112°F) freezers and dry ice transportation. Labels can be printed with all major brands of thermal-transfer printers. </p> <p><strong>Features: </strong> </p> <ul><li>Resistant to extreme cryogenic conditions - as low as -269°C </li> <li>Require zero cure time, can be immersed in liquid nitrogen immediately following application </li> <li>Adhere to wet and moist surfaces </li> <li>Labels are resistant to spraying and swabbing with alcohol and surface sanitizing wipes </li> <li>Permanent adhesion, especially on curved surfaces (vials, microtubes, etc.) </li> <li>Resistant to gamma irradiation (tested to up to 50kGy) </li> </ul> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Roll of 1000 Labels </td> </tr> </table>
<p><strong>GA International also known as LabTAG, JTTA-181C1-1RE, Nitrotag Cryogenic Barcode Label for Liquid Nitrogen Storage, 2.75" x 1.5", 1" Core, Red </strong> </p> <p>Cryogenic labels for the identification of small diameter vials & tubes, plates, cardboard freezer boxes, polypropylene cryo boxes, and plastic bags. Designed for long-term cryo-preservation under cryogenic laboratory conditions including liquid helium (-269°C / -452.2°F), liquid and vapor phase liquid nitrogen (-196°C / -320.8°F), -80°C (-112°F) freezers and dry ice transportation. Labels can be printed with all major brands of thermal-transfer printers. </p> <p><strong>Features: </strong> </p> <ul><li>Resistant to extreme cryogenic conditions - as low as -269°C </li> <li>Require zero cure time, can be immersed in liquid nitrogen immediately following application </li> <li>Adhere to wet and moist surfaces </li> <li>Labels are resistant to spraying and swabbing with alcohol and surface sanitizing wipes </li> <li>Permanent adhesion, especially on curved surfaces (vials, microtubes, etc.) </li> <li>Resistant to gamma irradiation (tested to up to 50kGy) </li> </ul> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Roll of 1000 Labels </td> </tr> </table>
<p><strong>GA International also known as LabTAG, JTTA-19C1-1WH, Nitrotag Cryogenic Barcode Label for Liquid Nitrogen Storage, 1.3" x 0.625", 1" Core </strong> </p> <p>Cryogenic labels for the identification of small diameter vials & tubes, plates, cardboard freezer boxes, polypropylene cryo boxes, and plastic bags. Designed for long-term cryo-preservation under cryogenic laboratory conditions including liquid helium (-269°C / -452.2°F), liquid and vapor phase liquid nitrogen (-196°C / -320.8°F), -80°C (-112°F) freezers and dry ice transportation. Labels can be printed with all major brands of thermal-transfer printers. </p> <p><strong>Features: </strong> </p> <ul><li>Resistant to extreme cryogenic conditions - as low as -269°C </li> <li>Require zero cure time, can be immersed in liquid nitrogen immediately following application </li> <li>Adhere to wet and moist surfaces </li> <li>Labels are resistant to spraying and swabbing with alcohol and surface sanitizing wipes </li> <li>Permanent adhesion, especially on curved surfaces (vials, microtubes, etc.) </li> <li>Resistant to gamma irradiation (tested to up to 50kGy) </li> </ul> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Roll of 1000 Labels </td> </tr> </table>
<p><strong>GA International also known as LabTAG, JTTA-500NOTC3-8MC, NitroTAG Cryogenic Barcode Labels – 0.5" Circle </strong> </p> <p><strong>Features: </strong> </p> <ul><li>Resistant to extreme cryogenic conditions – as low as -269°C </li> <li>Require zero cure time, can be immersed in liquid nitrogen immediately following application </li> <li>Adhere to wet and moist surfaces </li> <li>Labels are resistant to spraying and swabbing with alcohol and surface sanitizing wipes </li> <li>Permanent adhesion, especially on curved surfaces (vials, microtubes, etc.) </li> <li>Resistant to gamma irradiation (tested to up to 50kGy) </li> </ul> <p>Cryogenic labels for the identification of small diameter vials & tubes, plates, cardboard freezer boxes, polypropylene cryo boxes, and plastic bags. Designed for long-term cryo-preservation under cryogenic laboratory conditions including liquid helium (-269°C / -452.2°F), liquid and vapor phase liquid nitrogen (-196°C / -320.8°F), -80°C (-112°F) freezers and dry ice transportation. Labels can be printed with all major brands of thermal-transfer printers. </p> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Roll of 8000 Labels </td> </tr> </table>
<p><strong>GA International also known as LabTAG, JTTA-61NPNOTC3-4OR, NitroTAG Cryogenic Barcode Labels – 0.354" Circle </strong> </p> <p><strong>Features: </strong> </p> <ul><li>Resistant to extreme cryogenic conditions – as low as -269°C </li> <li>Require zero cure time, can be immersed in liquid nitrogen immediately following application </li> <li>Adhere to wet and moist surfaces </li> <li>Labels are resistant to spraying and swabbing with alcohol and surface sanitizing wipes </li> <li>Permanent adhesion, especially on curved surfaces (vials, microtubes, etc.) </li> <li>Resistant to gamma irradiation (tested to up to 50kGy) </li> </ul> <p>Cryogenic labels for the identification of small diameter vials & tubes, plates, cardboard freezer boxes, polypropylene cryo boxes, and plastic bags. Designed for long-term cryo-preservation under cryogenic laboratory conditions including liquid helium (-269°C / -452.2°F), liquid and vapor phase liquid nitrogen (-196°C / -320.8°F), -80°C (-112°F) freezers and dry ice transportation. Labels can be printed with all major brands of thermal-transfer printers. </p> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Roll of 4000 Labels </td> </tr> </table>
<p><strong>GA International also known as LabTAG, JTTA-62C3-1RE, NitroTAG Cryogenic Barcode Labels – 4" x 2" </strong> </p> <p><strong>Features: </strong> </p> <ul><li>Resistant to extreme cryogenic conditions – as low as -269°C </li> <li>Require zero cure time, can be immersed in liquid nitrogen immediately following application </li> <li>Adhere to wet and moist surfaces </li> <li>Labels are resistant to spraying and swabbing with alcohol and surface sanitizing wipes </li> <li>Permanent adhesion, especially on curved surfaces (vials, microtubes, etc.) </li> <li>Resistant to gamma irradiation (tested to up to 50kGy) </li> </ul> <p>Cryogenic labels for the identification of small diameter vials & tubes, plates, cardboard freezer boxes, polypropylene cryo boxes, and plastic bags. Designed for long-term cryo-preservation under cryogenic laboratory conditions including liquid helium (-269°C / -452.2°F), liquid and vapor phase liquid nitrogen (-196°C / -320.8°F), -80°C (-112°F) freezers and dry ice transportation. Labels can be printed with all major brands of thermal-transfer printers. </p> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Roll of 1000 Labels </td> </tr> </table>
<p><strong>GA International also known as LabTAG, JTTA-9C3-1OR, NitroTAG Cryogenic Barcode Labels – 1.25" x 0.875" </strong> </p> <p><strong>Features: </strong> </p> <ul><li>Resistant to extreme cryogenic conditions – as low as -269°C. </li> <li>Require zero cure time, can be immersed in liquid nitrogen immediately following application. </li> <li>Adhere to wet and moist surfaces. </li> <li>Labels are resistant to spraying and swabbing with alcohol and surface sanitizing wipes. </li> <li>Permanent adhesion, especially on curved surfaces (vials, microtubes, etc.) </li> <li>Resistant to gamma irradiation (tested to up to 50kGy) </li> </ul> <p>Cryogenic labels for the identification of small diameter vials & tubes, plates, cardboard freezer boxes, polypropylene cryo boxes, and plastic bags. Designed for long-term cryo-preservation under cryogenic laboratory conditions including liquid helium (-269°C / -452.2°F), liquid and vapor phase liquid nitrogen (-196°C / -320.8°F), -80°C (-112°F) freezers and dry ice transportation. Labels can be printed with all major brands of thermal-transfer printers. </p> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Roll of 1000 Labels </td> </tr> </table>
<p><strong>GA International also known as LabTAG, PRF-242C3-1WH, ParafiTAG Xylene Resistant Labels </strong> </p> <p>Thermal transfer printable thermoplastic labels that adhere strongly to paraffin wax blocks and other hard to stick surfaces such as Teflon, Polytetrafluoroethylene (PTFE), Perfluoroalkoxy (PFA), Parchment paper, etc. ParafiTAG labels are water- and chemical- resistant, ideal for the identification of blocks of paraffin wax for histology applications. A chemical-resistant printout is obtained when printed with XAR class solvent-resistant ribbons. The labels and printed information will resist xylene, toluene, alcohol, and other solvents and chemicals exposure without additional protection. </p> <table cellspacing="1" cellpadding="2" border="0" width="100%" class="dataTable"><tr><td>Unit of Measure </td> <td>Roll of 1000 labels </td> </tr> </table>
<p><strong>GfG Instrumentation, 2901-09-008, IR 29E Methane Transmitter, Display, 4-20mA </strong> </p> <p>Unlike traditional LEL sensors, IR 29 transmitters do not need the presence of oxygen to detect gas. Since they are not affected by sensor poisons they don’t require periodic adjustment to make up for lost sensitivity. The IR 29 continuously monitors its functions for proper performance, and can even identify and communicate required service procedures. </p> <p>Acetylene, alcohols*, CO2 , fuel vapors**, saturated hydrocarbons***, unsaturated VOCs**** </p> <p><strong>Features: </strong> </p> <ul><li>ATEX: II II 2G Ex eb mb ib [ib] IIC T4 Gb </li> <li>Patented infrared technology (NDIR) </li> <li>Temperature, moisture and pressure compensation </li> <li>Maintenance and service-friendly </li> <li>4-20 mA, linear or digital (Modbus interface) </li> </ul> <p><strong>Response Time: </strong> </p> <ul><li>t 90 ≈ 35-50 seconds </li> </ul> <p><strong>Ambient Temperature </strong> : </p> <ul><li>Operation: -4°F to +131°F </li> <li>Storage: -13°F to +131°F </li> </ul> <p><strong>Housing Protection: </strong> </p> <ul><li>IP 67 </li> <li>V4A Stainless steel with polycarbonate </li> </ul> <p><strong>Humidity: </strong> </p> <ul><li>0 to 95% r.h. non-condensing </li> </ul> <p><strong>Output Signal: </strong> </p> <ul><li>4-20 mA </li> </ul> <p><strong>Power Supply: </strong> </p> <ul><li>15 to 30 V DC </li> </ul> <p>* Alcohols such as methanol, ethanol, isopropanol, etc... </p> <p>** Fuel vapors such as diesel, jet fuel, gasoline, etc... </p> <p>*** Saturated hydrocarbons such as methane, propane, butane, pentane, nonance, etc... </p> <p>**** Unsaturated VOCs such as MEK, toluene, butadiene, etc... </p>
<p><strong>GfG Instrumentation, 2901-37-007, IR 29E Propane Transmitter, No Display, 4-20mA </strong> </p> <p>Unlike traditional LEL sensors, IR 29 transmitters do not need the presence of oxygen to detect gas. Since they are not affected by sensor poisons they don’t require periodic adjustment to make up for lost sensitivity. The IR 29 continuously monitors its functions for proper performance, and can even identify and communicate required service procedures. </p> <p>Acetylene, alcohols*, CO2 , fuel vapors**, saturated hydrocarbons***, unsaturated VOCs**** </p> <p><strong>Features: </strong> </p> <ul><li>ATEX: II II 2G Ex eb mb ib [ib] IIC T4 Gb </li> <li>Patented infrared technology (NDIR) </li> <li>Temperature, moisture and pressure compensation </li> <li>Maintenance and service-friendly </li> <li>4-20 mA, linear or digital (Modbus interface) </li> </ul> <p><strong>Response Time: </strong> </p> <ul><li>t 90 ≈ 35-50 seconds </li> </ul> <p><strong>Ambient Temperature </strong> : </p> <ul><li>Operation: -4°F to +131°F </li> <li>Storage: -13°F to +131°F </li> </ul> <p><strong>Housing Protection: </strong> </p> <ul><li>IP 67 </li> <li>V4A Stainless steel with polycarbonate </li> </ul> <p><strong>Humidity: </strong> </p> <ul><li>0 to 95% r.h. non-condensing </li> </ul> <p><strong>Output Signal: </strong> </p> <ul><li>4-20 mA </li> </ul> <p><strong>Power Supply: </strong> </p> <ul><li>15 to 30 V DC </li> </ul> <p>* Alcohols such as methanol, ethanol, isopropanol, etc... </p> <p>** Fuel vapors such as diesel, jet fuel, gasoline, etc... </p> <p>*** Saturated hydrocarbons such as methane, propane, butane, pentane, nonance, etc... </p> <p>**** Unsaturated VOCs such as MEK, toluene, butadiene, etc... </p>
<p><strong>Heskins, CR_NMKIII_19, MK3 Coarse Resilient Anti Slip Tape, Black, 19" x 60' </strong> </p> <p>Coarse resilient tape is constructed from an embossed plastic, with an embossing technique applied that allows for an excellent surface texture that has high levels of CoF (Coefficient of Friction) while being non abrasive. </p> <p><strong>Anti Slip Stair Edging </strong> </p> <p>On construction sites and in other industrial environments, steps and stairs are exposed to the elements, and the elements are also brought indoors by the user, causing stairs to become hazardous, and therefore increasing the chance of slips. Walkways in and around buildings, and footplates and steps on machinery are all prone to the same outcome. Applying anti slip stair strips as anti slip stair edging to these areas will help to reduce slips, with the industrial finish preventing the dirt and other contaminants from degrading performance to levels that do not meet regulation </p> <p><strong>Features: </strong> </p> <ul><li>Easy to clean </li> <li>No grit to shed </li> <li>Kind to skin and clothing </li> <li>Waterproof </li> <li>For more demanding areas </li> </ul>
<p><strong>Heskins, CR_NMKIII_45, MK3 Coarse Resilient Anti Slip Tape, Black, 45" x 60' </strong> </p> <p>Coarse resilient tape is constructed from an embossed plastic, with an embossing technique applied that allows for an excellent surface texture that has high levels of CoF (Coefficient of Friction) while being non abrasive. </p> <p><strong>Anti Slip Stair Edging </strong> </p> <p>On construction sites and in other industrial environments, steps and stairs are exposed to the elements, and the elements are also brought indoors by the user, causing stairs to become hazardous, and therefore increasing the chance of slips. Walkways in and around buildings, and footplates and steps on machinery are all prone to the same outcome. Applying anti slip stair strips as anti slip stair edging to these areas will help to reduce slips, with the industrial finish preventing the dirt and other contaminants from degrading performance to levels that do not meet regulation </p> <p><strong>Features: </strong> </p> <ul><li>Easy to clean </li> <li>No grit to shed </li> <li>Kind to skin and clothing </li> <li>Waterproof </li> <li>For more demanding areas </li> </ul>
<p><strong>In-Line Flow Monitor, Aluminum body, 1/2" Female NPT Dry Seal, range 5-50 SCFM Air. </strong> </p> <strong>Low Cost, Series HF In-Line Flow Monitors </strong> have a design based on a floating sharp-edged orifice disk and variable area flow measurement to yield accuracy of ±2.5% over center one-third of scale. This unique design allows accurate performance with fluid viscosities up to 500 SSU. All internal wetted parts are contained inside a sealed metal tubular casing assuring a virtually maintenance-free unit. Flowing media forces linear motion of a spring loaded, sharp edge orifice disk and ring shaped transfer magnet which both ride on a tapered center shaft. The transfer magnet drives a clearly visible magnet follower located outside the flow tube, protected under the clear polycarbonate tube. A ring on the magnet follower indicates flow rate on the direct reading scale. Rubber bumpers are provided for external impact resistance.<p>Designed for single-direction flow, Series HF Monitors are recommended for use with system filtration of at least 74 microns or a 200 mesh screen. Some applications may also require magnetic filtration. These flowmeters do not require inlet or outlet straight plumbing and can be mounted horizontally, vertically, or inverted. </p> <p><strong>Applications: </strong> </p> <ul> <li> Used to set flow rates, fluid motor and cylinder speeds. </li> <li> Check pump high pressure performance, pressure relief valve settings, fluid handling systems in agricultural, construction or industrial machinery, power tools and equipment. </li> <li> Monitor petrochemical operations with brass or stainless steel models. </li> <li> Industrial pneumatic systems air flow can be monitored with the HFA models which are calibrated at 100 psig inlet pressure. </li> </ul>
<p><strong>Includes: </strong> </p> <ul><li>1 pce detachable square driver blade stubby ratcheting screwdriver </li> <li>8 pcs S2 Zinc Phosphate bits: PH 1, PH 2, PZ 1, PZ 2, T-15, T-20, SL 4, HEX 3 </li> <li>1 pce 1/4 x 1/4" socket adapter </li> <li>1 pce 1/4 Sq. x 1/4" hex bit holder 50 mm (changeable type) </li> <li>1 pce 1/4 Sq. x 1/4" square flexible socket adapter 150 mm </li> <li>1 pce 1/4 x 1/4" bit adapter </li> <li>5 pcs 1/4" sockets: 4, 5, 6, 7, 8 mm </li> </ul> <p><strong>Features: </strong> </p> <ul><li>Stubby ratcheting 1/4" bit holder, bits and sockets set </li> <li>Lightweight, rounded corners handy injection case </li> <li>Detachable square driver blade </li> </ul> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Set of 18 pcs </td> </tr> </table>
<p><strong>International Enviroguard, 7219GT-4XL, ChemSplash 2 Chemical Splash Coverall, Attached Hood and Boot, Elastic Wrists, Taped Seams, 4XL </strong> </p> <p>Disposable coveralls designed for protection against a broad range of acids and caustic chemicals. Lighter and more pliable proprietary fabric vs competitive coveralls provides worker comfort. Taped seams improve protection vs coveralls made with serged seams. Recommended applications include emergency response, chemical loading, petrochemical environments and more. </p> <p><strong>Features: </strong> </p> <ul><li>Light, pliable fabric for more comfortable wear </li> <li>Roomy, seamless shoulder area resists tears and provides more protection in key exposure area </li> <li>Wider, gusseted crotch gives wearer more room to move in all directions without ripping fabric </li> <li>Elastic back stretches with user for more comfort and better tear resistance </li> <li>Storm flap over zipper with pressure sensitive tape adds an extra layer of protection </li> </ul> <p> <img src="//usmegastore.com/assets_images/depiction/international-enviroguard/2012-L_d1.jpg" style="width:60%" /> </p> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Case of 6 pcs </td> </tr> </table>
<p><strong>J.G. Finneran Associates, MSC95E-12A, Mass Spec Certified Amber glasss 9mm R.A.M.™ Vial w/Grad SpOpen Top, 12 x 32mm, w/PP Open Top Cap, Royal Blue, Bonded PTFE/Silicone </strong> </p> <p><strong>Features: </strong> </p> <ul><li>glasss – Type 1, Class A, 51A Amber Borosilicate </li> <li>Dimensions – Height, Diameter, Bottom Thickness, Neck Length, Th read Profile, Annealing </li> <li>Cap/Septum – Diameter, Height, Th read Integrity, Center Flash, Septa Insertion </li> <li>GC/MS Background Test </li> <li>LC/MS Background Test </li> <li>Particle Counts – Particle Size, Particle/mL/Vial </li> </ul> <table class="dataTable" border="0" width="100%" cellspacing="1" cellpadding="2"><tr><td>Unit of Measure </td> <td>Pack of 100 pcs </td> </tr> </table>